Intelligent rack mounted cabinet controller with equipment level surge protection, remote power management, environmental monitoring and access control.
NLMNDBNT3EQ-2U32 Intelligent EQ Cabinet Controller 19 Inch 2U – 32Amp with Integrated Monitored Equipment Level Surge protection, IoT/Cloud – Web – SNMP managed with birds eye view dashboards, remote configurable and managed from a single IP address, Integrated compact type 3 surge protection with automatic remote failure detection & local indication window, dedicated Air conditioner C19 power socket & control and monitoring dry contacts, Internal switched PDU with Class 1 Metering & 2 x C13 & 4 x C19 & 1 x C19 expansion PDU IEC type socket, Front door e-lock control with monitoring door contact, Wiegand access control interface (Keypad, Biometric or RFID), Rear door e-lock control with monitoring door contact, Dual 1-wire Temperature sensors (up to 5) included, Single flooding/water rope sensors included, RS485 phantom power expansion sensor interface for (optional) Humidity sensor, NC/NO inputs for (optional) Optical Smoke Detector & Current loop Control for (optional) Fire Extinguisher, RS485/232 Serial UPS Management with C19 feeding socket & C20 return plug (up to 4.4KVA), (optional) USB/GSM Modem for emergency reporting.
NLMNDBNT3EQ-3U32 Intelligent EQ Cabinet Controller 19 Inch 3U – 32Amp with Integrated Monitored Equipment Level Surge protection, IoT/Cloud – Web – SNMP managed with birds eye view dashboards, remote configurable and managed from a single IP address, Integrated compact type 3 surge protection with automatic remote failure detection & local indication window, dedicated Air conditioner C19 power socket & control and monitoring dry contacts, Internal switched PDU with Class 1 Metering & 8 x C13 & 4 x C19 & 1 x C19 expansion PDU IEC type socket, Front door e-lock control with monitoring door contact, Wiegand access control interface (Keypad, Biometric or RFID), Rear door e-lock control with monitoring door contact, Dual 1-wire Temperature sensors (up to 5) included, Single flooding/water rope sensors included, RS485 phantom power expansion sensor interface for (optional) Humidity sensor, NC/NO inputs for (optional) Optical Smoke Detector & Current loop Control for (optional) Fire Extinguisher, RS485/232 Serial UPS Management with Hubbell/Terminal block feeding socket & return plug (up to 7KVA), (optional) USB/GSM Modem for emergency reporting.
NLMNDBLT1P-2U32 Intelligent Distribution Cabinet Controller 19 Inch 2U – 15Amp with Integrated Monitored type 1 + 2 surge Compact protection Surge protection, IoT/Cloud – Web – SNMP managed with birds eye view dashboards, remote configurable and managed from a single IP address, Integrated compact type 3 surge protection with automatic remote failure detection & local indication window, Dual dedicated Air conditioner C19 power socket & control and monitoring dry contacts, Internal switched PDU with Class 1 Metering & 4 x C13 & 3 x C19 & 1 x C19 expansion PDU IEC type socket, Front door e-lock control with monitoring door contact, Wiegand access control interface (Keypad, Biometric or RFID), Rear door e-lock control with monitoring door contact, Dual 1-wire Temperature sensors (up to 5) included, Single flooding/water rope sensors included, RS485 phantom power expansion sensor interface for (optional) Humidity sensor, NC/NO inputs for (optional) Optical Smoke Detector & Current loop Control for (optional) Fire Extinguisher, RS485/232 Serial UPS Management with C19 feeding socket & C20 return plug (up to 4.4KVA), (optional) USB/GSM Modem for emergency reporting.
NLMNDBNT1P-3U32 Intelligent Core Cabinet Controller 19 Inch 3U – 32Amp with Integrated Monitored type 1 + 2 surge Compact protection with automatic switch over fault/failure detection Surge protection, IoT/Cloud – Web – SNMP managed with birds eye view dashboards, remote configurable and managed from a single IP address, Integrated compact type 3 surge protection with automatic remote failure detection & local indication window, Dual dedicated Air conditioner C19 power socket & control and monitoring dry contacts, Dual Internal switched PDU with Class 1 Metering & 4 x C13 & 3 x C19 & 1 x C19 expansion PDU IEC type socket, Front door e-lock control with monitoring door contact, Wiegand access control interface (Keypad, Biometric or RFID), Rear door e-lock control with monitoring door contact, Dual 1-wire Temperature sensors (up to 5) included, Single flooding/water rope sensors included, RS485 phantom power expansion sensor interface for (optional) Humidity sensor, NC/NO inputs for (optional) Optical Smoke Detector & Current loop Control for (optional) Fire Extinguisher, RS485/232 Serial UPS Management with Hubbell/Terminal block feeding socket & return plug (up to 7KVA), dual optically isolated X21 Interfaces and (optional) USB/GSM Modem for emergency reporting.
NLMNDBNT3P-3U32 Intelligent Core Cabinet Controller 19 Inch 3U – 32Amp with Integrated Dual Monitored type 1 + 2 surge Compact protection with automatic switch over fault/failure detection Surge protection, IoT/Cloud – Web – SNMP managed with birds eye view dashboards, remote configurable and managed from a single IP address, Integrated compact type 3 surge protection with automatic remote failure detection & local indication window, Dual dedicated Air conditioner C19 power socket & control and monitoring dry contacts, Dual Internal switched PDU with Class 1 Metering & 4 x C13 & 3 x C19 & 1 x C19 expansion PDU IEC type socket, Front door e-lock control with monitoring door contact, Wiegand access control interface (Keypad, Biometric or RFID), Rear door e-lock control with monitoring door contact, Dual 1-wire Temperature sensors (up to 5) included, Single flooding/water rope sensors included, RS485 phantom power expansion sensor interface for (optional) Humidity sensor, NC/NO inputs for (optional) Optical Smoke Detector & Current loop Control for (optional) Fire Extinguisher, RS485/232 Serial UPS Management with Hubbell/Terminal block feeding socket & return plug (up to 7KVA), dual optically isolated X21 Interfaces and (optional) USB/GSM Modem for emergency reporting.

.

Features MODELS
NLMNDBNT3EQ-2U15 NLMNDBNT3EQ-2U32 NLMNDBLT1P-2U15 NLMNDBLT1P-3U15 NLMNDBLT3P-3U15 NLMNDBNT1P-3U32 NLMNDBNT3P-3U32
Can be used with 220V UPS with a maximum size of: 4.4kVA 7.5kVA 4.4kVA 4.4kVA 4.4kVA 7.5kVA 7.5kVA
Circuit breaker maximum current (A) at 220V 15A 32A 15A 15A 15A 32A 32A
19″ Rack mounting Cabinet space 2U 2U 2U 3U 3U 3U 3U
Surge Protection
Integrated Surge Protector TYPE 3 3 1+2 1+2 1+2 1+2 1+2
Surge Protection stages Single Single Single 3 3 Single 3
Automatic remote surge protection failure detection and failure indicator on protection module Yes Yes Yes Yes Yes Yes Yes
Power
Power Sockets for air conditioners and NTU 1x C19 Power Socket Optional 2x 3PinSA if no X21 interface present 1x C19 Power Socket Optional 2x 3PinSA if no X21 interface present 1x C19 Power Socket Optional 2x 3PinSA if no X21 interface present 2x 3PinSA + 3x C19 Power Socket 2x 3PinSA + 3x C19 Power Socket 2x 3PinSA + 3x C19 Power Socket 2x 3PinSA + 3x C19 Power Socket
PDU’s – Rear Panel Mounted with Metering and remote switchable Single bank of 4 x C13 and 3 x C19 Single bank of 4 x C13 and 3 x C19 Single bank of 4 x C13 and 3 x C19 Dual Bank of 4 x C13 and 4 x C19 Dual Bank of 4 x C13 and 4 x C19 Dual Bank of 4 x C13 and 4 x C19 Dual Bank of 4 x C13 and 4 x C19
PDU Expansion C19 Expansion Connector. To Expand to a Choice of RS485 Controlled Optional PDU’s C19 Socket C19 Socket C19 Socket C19 Socket C19 Socket C19 Socket C19 Socket
Power Feed to Cabinet – 3 Meter Cable on mounted plug directly into the unit Hubble Plug Hubble Plug Hubble Plug Hubble Plug Hubble Plug Hubble Plug Hubble Plug
Power feed to UPS C19 Socket Cable mounted Hubble Socket C19 Socket Cable mounted Hubble Socket Cable mounted Hubble Socket Cable mounted Hubble Socket Cable mounted Hubble Socket
Re-enter Power feed from UPS C20 Socket Cable mounted Hubble Socket C20 Socket Cable mounted Hubble Socket Cable mounted Hubble Socket Cable mounted Hubble Socket Cable mounted Hubble Socket
The UPS feed to and from unit can be connected to manually bypass the UPS C20 to C19 Lead Hubble Socket to Plug C20 to C19 Lead Hubble Socket to Plug Hubble Socket to Plug Hubble Socket to Plug Hubble Socket to Plug
Power Metered and Monitored with under/over voltage/current/consumption alarms – Setup and Alerts through SNMP/SMS Yes (1 Units Included) Yes (1 Units Included) Yes (1 Units Included) Yes (3 Units Included) Yes (3 Units Included) Yes (3 Units Included) Yes (3 Units Included)
Manual and Remote unit mains ON/OFF – with reporting and set Via SNMP/SMS Yes Yes Yes Yes Yes Yes Yes
UPS bypass mode : Manual, Local and Remote controllable – with Error reporting and set Via SNMP/SMS No Yes Yes Yes Yes Yes Yes
Systems backup Battery, Battery Charger and Battery SoC Monitoring Yes Yes Yes Yes Yes Yes Yes
Earthing Stud Yes Yes Yes Yes Yes Yes Yes
UPS
Modbus Communication to UPS via either RS485 or RS232 Yes Yes Yes Yes Yes Yes Yes
X.21
Slot for Up to 3 x X.21/V11 Optically Isolation Modules with Interface Present and Data Active Flow Control Monitoring and Error reporting Via SNMP/SMS Optional Optional Optional Optional Optional Yes Yes
X21 Cable _DB15 Male to Female 1.5 Meter include Optional Optional Optional Optional Optional Yes Yes
Environmental monitoring
1 Wire Temperature Sensors – 2 x Temperature (expandable to 8 units) with Error reporting Via SNMP /SMS Yes (2 Units Included) Yes (2 Units Included) Yes (2 Units Included) Yes (2 Units Included) Yes (2 Units Included) Yes (2 Units Included) Yes (2 Units Included)
Water Flooding/Leak Detection sensor with Error reporting Via SNMP/SMS Yes (2 Units Included) Yes (2 Units Included) Yes (2 Units Included) Yes (2 Units Included) Yes (2 Units Included) Yes (2 Units Included) Yes (2 Units Included)
Humdity sensor with Error reporting Via SNMP/SMS Optional Optional Optional Optional Optional Optional Optional
Access Control
Door Maglock/Actuator set control Interface with Battery Backup 3 x 12VDC feeding Output 3 x 12VDC feeding Output 3 x 12VDC feeding Output 3 x 12VDC feeding Output 3 x 12VDC feeding Output 3 x 12VDC feeding Output 3 x 12VDC feeding Output
Wiegand Access control 1 x Wiegand Interface and 125kHz keypad and proximity card reader 1 x Wiegand Interface and 125kHz keypad and proximity card reader 1 x Wiegand Interface and 125kHz keypad and proximity card reader 1 x Wiegand Interface and 125kHz keypad and proximity card reader 1 x Wiegand Interface and 125kHz keypad and proximity card reader 1 x Wiegand Interface and 125kHz keypad and proximity card reader 1 x Wiegand Interface and 125kHz keypad and proximity card reader
Door switches to Monitor the Front/Rear/Side Door of cabinets 3 included 3 included 3 included 3 included 3 included 3 included 3 included
Fire protection
Fire extinguisher controller port (Current loop) 1 1 1 1 1 1 1
Smoke detector input NO and NC 1 1 1 1 1 1 1
Air Conditioner
Air Conditioner Control Interface 1 X Input STATE and 1 Output ON/OFF 1 X Input STATE and 1 Output ON/OFF 1 X Input STATE and 1 Output ON/OFF 1 X Input STATE and 1 Output ON/OFF 1 X Input STATE and 1 Output ON/OFF 1 X Input STATE and 1 Output ON/OFF 1 X Input STATE and 1 Output ON/OFF
Networking and remote monitoring
10/100BaseT networking port with SNMP – (5 Meter Patch lead Included) Yes Yes Yes Yes Yes Yes Yes
DHCP Default Network configuration DHCP enabled DHCP enabled DHCP enabled DHCP enabled DHCP enabled DHCP enabled DHCP enabled
Centralized monitoring with SNMP – 4 Programmable Destinations IP addresses Yes Yes Yes Yes Yes Yes Yes
Remote Power monitoring, control and configuration with SNMP Yes Yes Yes Yes Yes Yes Yes
Remote Environmental monitoring, control and configuration with SNMP Yes Yes Yes Yes Yes Yes Yes
Remote Access monitoring, control and configuration with SNMP Yes Yes Yes Yes Yes Yes Yes
Display
Local Alarm Indication on Full Colour LCD Yes Yes Yes Yes Yes Yes Yes
WEB Number, Site address Detail and Unit Serial Numbers configuration through SNMP – LCD displayed Yes Yes Yes Yes Yes Yes Yes
GSM
GSM Modem with Conditional SMS Alerting and Configuration Optional Optional Optional Optional Optional Optional Optional
Power cords
C20 to C19 power cords 1.5 to 1.8M (IEC 60320) None None 4 4 2 2 2
C13 to C14 power cords 1.5 to 1.8M (IEC 60320) None None 2 2 4 4 4
Warranty Life Time Life Time Life Time Life Time Life Time Life Time Life Time
Optional PDU’s
RS485 MB Monitored and Metered PDU C20 Pluggable – 1U Rack mountable with 4 X C19 Sockets and 8 X C13 Sockets Optional Optional Optional Optional Optional Optional Optional
RS485 MB Monitored and Metered PDU C20 Pluggable – 1U Rack mountable with 4 X C15 Sockets and 8 X C13 Sockets Optional Optional Optional Optional Optional Optional Optional
RS485 MB Monitored and Metered PDU C20 Pluggable – 1U Rack mountable with 4 x 3 Prong SA Standard Sockets. Optional Optional Optional Optional Optional Optional Optional
Additional Optional Devices
Temperature sensors (1-Wire) Optional Optional Optional Optional Optional Optional Optional
Humidity sensors Optional Optional Optional Optional Optional Optional Optional
Rope Flooding Sensors Optional Optional Optional Optional Optional Optional Optional
Smoke detectors Optional Optional Optional Optional Optional Optional Optional
Smother fire extinguisher Optional Optional Optional Optional Optional Optional Optional